Explore Veawe’s Advanced Modbus IO Modules for Industrial Automation & IoT
2 Channel Analog Input Modbus RTU RS485 Module
- One 0 – 20mA and one 0 – 36V DC Analog Inputs
- 16-bit analog resolution
- Modbus RS-485 Protocol Interface.
- Integer and IEEE754 float value support
- Offset and Gain support
- Convenient address selection dip switch from 1 – 15 Address
- Complete range of baud rate settings supported
- Sensor open indication, Analog values in integer and float values
- DIN Rail mount support
- Product Dimensions 60mm x 50mm x 20mm (L x W x H)
2 Channel Digital Input Modbus RTU RS485 Module
2 Channel Digital Output Modbus RTU RS485 Module
2CH Modbus to 20mA Analog Output – UIO-2AO
Features
● Two Channel 0 ~ 20mA Output
● Modbus RS-485 Protocol Interface.
● Resolution at 0.02 mA
● Convenient address selection rotatory switch from 1 – 99 Address
● Complete range of baud rate settings supported
● Suitable for both Din Rail and Wall Mountable
● Product Dimensions 110mm x 50mm x 55mm (L x W x H)
4 Channel 10v Modbus UIO-4IN-10v
4 Channel 20mA Modbus UIO-4IN-20mA
4 Digital Input 4 Digital Output Modbus Module UIO-4DI4DO
- 4 digital inputs and 4 digital outputs with LED indication for all IO’s
- RS485 interface output with Modbus RTU Slave
- Suitable for all types of Industrial Machine Automation, IoT, IO Expansion, Remote monitoring
- ● Convenient address selection rotatory switch from 1 – 99 Address
- ● Complete range of baud rate settings supported
- ● Suitable for both Din Rail and Wall Mountable
● Product Dimensions 110mm x 50mm x 55mm (L x W x H)
4CH Modbus to 20mA Analog Output – UIO-4AO
Features
● Four Channel 0 ~ 20mA Output
● Modbus RS-485 Protocol Interface.
● Resolution at 0.02 mA
● Convenient address selection rotatory switch from 1 – 99 Address
● Complete range of baud rate settings supported
● Suitable for both Din Rail and Wall Mountable
● Product Dimensions 110mm x 50mm x 55mm (L x W x H)
8 Channel 20mA Modbus Input Module UIO-8IN-20mA
Key Features
- 8 Channel 0–20mA Analog Inputs
- 16-bit analog resolution
- Factory calibrated accuracy: ± 0.1% from upper-range
- Raw analog value resolution in steps of 0.001mA
- Sensor open / broken wire indication
- Configurable individual alarms indication
- Retentive alarm counters on power cycle
- Individual channel offset and gain calibration
- Integer and IEEE754 float value support
- Modbus RTU over Isolated RS-485
- Modbus RTU remote write master mode
- Easy to use free ModViz software
- Rotary address switch for address selection from 1 to 99
- Wide Supported baud rates from 300 to 115200
- DIN rail mountable
- Dimensions: 110mm × 50mm × 55mm
8 Channel 4x 20mA + 4x 10V Modbus Input Module UIO-8IN-VI
Key Features
- 4 Channel 0–20mA Analog Inputs (CH1–CH4)
- 4 Channel 0–10V Analog Inputs (CH5–CH8)
- 16-bit analog resolution
- Factory calibrated accuracy: ± 0.1% from upper-range
- Raw analog value resolution in steps of 0.001mA (CH1–CH4) & 0.001V (CH5–CH8)
- Sensor open / broken wire indication
- Configurable individual alarms indication
- Retentive alarm counters on power cycle
- Individual channel offset and gain calibration
- Integer and IEEE754 float value support
- Modbus RTU over Isolated RS-485
- Modbus RTU remote write master mode
- Easy to use free ModViz software
- Rotary address switch for address selection from 1 to 99
- Wide Supported baud rates from 300 to 115200
- DIN rail mountable
- Dimensions: 110mm × 50mm × 55mm
8 Input Modbus Module UIO-8DI
8 Output Modbus Module UIO-8DO
Welcome to Veawe’s Modbus IO Module category, where precision meets reliability in industrial communication. Our extensive range of Modbus RTU modules is engineered to seamlessly bridge field sensors, actuators, and industrial machinery with SCADA systems, PLCs, and IoT networks.
Designed for robust performance in harsh environments, Veawe Modbus modules support standard RS-485 communication interfaces utilizing the widely adopted Modbus RTU protocol. Whether you are expanding your system’s capabilities or setting up a new remote monitoring architecture, our product lineup features:
Analog Input/Output Modules: High-resolution (up to 16-bit/20-bit) modules tailored for 0–20mA, voltage signals, load cells, and temperature sensors.
Digital I/O Modules: Compact and high-density units offering flexible configurations of digital inputs (DI) and digital outputs (DO/Relay) complete with LED status indicators.
Specialized Multi-Function & Sensor Modules: Dedicated interfaces for environmental monitoring (temperature and humidity), production counting, and RPM measurement.
Key Features of Veawe Modbus Modules:
Seamless Integration: Compatible with standard Modbus RTU master devices and supported by user-friendly configuration tools like ModViz.
Flexible Addressing & Baud Rates: Equipped with convenient DIP or rotary switches for effortless slave ID configuration (1 to 99) alongside a broad range of baud rate options.
DIN Rail & Wall Mountable: Space-saving, rugged form factors designed for hassle-free installation in control panels.
Data Flexibility: Native support for both integer and IEEE 754 floating-point value formats.
Browse our catalog below to find the ideal remote I/O solution optimized for your specific industrial application, machine automation, or smart factory upgrade.