Skip to content

Loadcell Amplifier - ±10V

Bipolar Load Cell Amplifier ±10V AC-LD-B10 Datasheet pdf

The AC-LD-B10 (UC-LD-±10V) is an industrial bipolar strain gauge load cell signal conditioner engineered to convert bidirectional bridge sensor outputs into a calibrated -10V to +10V DC (\(\pm 10\text{V}\)) analog voltage signal. Specially designed for bidirectional force measurement—such as tension and compression testing, push-pull dynamics, and bidirectional torque—it integrates a regulated sensor excitation supply, front-panel multi-turn Zero and Span calibration potentiometers, and an ultra-fast response time of less than 1 ms. It delivers precise, linear signal conversion directly to industrial PLCs, PACs, and high-speed data acquisition systems.

Product image

Key Features

  • Bidirectional full-bridge load cell input for tension/compression sensing
  • Built-in precision regulated bridge excitation supply
  • Calibrated ±10V DC bipolar linear analog output (< 0.5% ripple noise)
  • Ultra-fast response time (< 1 ms) for dynamic material and torque testing
  • Front-panel multi-turn Zero and Span calibration potentiometers
  • Continuous output short-circuit and input reverse polarity protection
  • ±15 kV ESD protection across all signal and power terminals
  • 24V DC industrial power supply input (18V to 30V DC)
  • 35 mm DIN rail and wall mountable housing
  • Dimensions: 110 mm × 50 mm × 55 mm

Ordering Information

Product Code Description
AC-LD-B10 Bipolar Load Cell Amplifier ±10V (Bidirectional Tension/Compression, DIN Rail / Wall Mount)
AC-LD-10 Load Cell Amplifier 0–10V (24V DC, DIN Rail / Wall Mount)
AC-LD-20mA Load Cell Amplifier 4–20mA / 0–20mA (1.1k \(\Omega\) Load, 24V DC)
MIO-1LD Loadcell to Modbus RTU RS485 Transmitter
USS10V24V-D Voltage Source Simulator 0-10V with Display
SPD-24V-DC Surge Protection Device 24V DC

Applications

  • Bidirectional Tension & Compression Testing: Measuring both tensile and compressive loads on universal testing machines and load frames.
  • Push-Pull Force Measurement: Real-time force verification in automated insertion, crimping, and assembly equipment.
  • Bidirectional Torque & Shaft Sensing: Amplifying torque transducer signals rotating in clockwise and counter-clockwise directions.
  • Dynamic Material Testing & Impact Analysis: Sub-millisecond response enables high-speed capture of sudden shock and cyclic strain.
  • Industrial Automation & Robotics: Providing balanced bidirectional force feedback for robotic grippers and automated actuators.

Specifications

Parameter Value
Mounting Type 35 mm DIN Rail & Wall Mounting
Dimensions 110 mm x 50 mm x 55 mm (L x W x H)
Weight 100 g
Enclosure Material Industrial Grade ABS
Operating Temperature 0 °C to +55 °C
Storage Temperature -40 °C to +85 °C
Relative Humidity 5% to 95% RH (non-condensing)

Electrical Specifications

Parameter Specification
Power Supply Voltage 24V DC
Operating Current 200 mA @ 24V DC
Sensor Input Type Full-bridge strain gauge load cell with excitation source (unidirectional & bidirectional)
Sensor Excitation Output Integrated precision excitation supply (EX+, EX-)
Output Signal Range -10.00 V to +10.00 V DC (\(\pm 10\text{V}\))
Accuracy < \(\pm 1\%\) of Full Scale @ 25 °C ambient temperature
Output Ripple Noise < 0.5% of Full Scale
Response Time < 1 ms (< 1 milliSec)
Output Short Circuit Protection 20 mA @ 10V continuous limiting
Reverse Polarity Protection Integrated diode on 24V DC input
ESD Protection \(\pm 15\text{kV}\) Air / HBM, Contact discharge across all I/O pins

Calibration Procedure

The front-panel multi-turn trimpots allow precision field calibration:

  1. Zero Offset Calibration:
  2. Install the bidirectional load cell sensor in its mechanical fixture with zero net load applied (tare condition).
  3. Measure the output voltage between terminals OUT + and OUT - using a calibrated digital multimeter.
  4. Adjust the front ZERO potentiometer until the output reads \(\approx 0.00\text{ V}\).
  5. Span Calibration:
  6. Apply a known certified reference load (in positive tension or compression) corresponding to full scale.
  7. Adjust the front SPAN potentiometer until the output reads \(\approx +10.00\text{ V}\) (or proportional positive voltage).
  8. Bidirectional Verification:
  9. Apply reverse load (e.g. compression if tension was calibrated, or vice-versa) and verify negative voltage response down to \(-10.00\text{ V}\).
  10. Remove load and verify that the output cleanly returns to \(0.00\text{ V}\).

Mechanical Dimensions

Mechanical dimensions

Terminal Details & Port Pinouts

Loadcell Sensor & Power Connections

Terminal Block Pin Label Signal Description
Loadcell Terminal 1 EX+ Excitation (+) Precision positive excitation voltage to load cell
(Top 5-Pin Block) 2 S+ Signal (+) Positive differential signal input from load cell
3 SLD Shield Cable shield connection (Earth ground)
4 S- Signal (-) Negative differential signal input from load cell
5 EX- Excitation (-) Negative excitation return to load cell
DC Power 1 V+ Power Input +24V DC Operating Power Supply
(Bottom Left) 2 V- Power Ground 0V Power Ground Return
±10V Output 1 OUT + Voltage Out (+) Calibrated Bipolar -10V to +10V DC Analog Output
(Bottom Right) 2 OUT - Voltage Out (-) Analog Signal Ground Return

LED Indications and Diagnostics

LED Color Status Description
PWR Green ON Operating power connected and bridge excitation active

Revision History

Revision Date Description of Change
Rev 1.0 2026-09-09 Initial datasheet release

Get the latest version of this datasheet : click here..

Support

Website: www.veawe.io

Email: info@veawe.io